Skip to main content
MCP server CX Codex

Sartorius Balance — Claude Code MCP server: weighing via SBI protocol

Sartorius Balance — an MCP server for Sartorius laboratory balances over SBI protocol. The agent weighs samples, tares containers, logs drift and runs internal adjustments.

Apache-2.0 ★ 32 updated 2026-09-26

Install into Claude Code · Platform CLI All methods and platforms ↓
claude mcp add --env LABMCP_ADDRESS=<LABMCP_ADDRESS> --env LABMCP_SIMULATE=<LABMCP_SIMULATE> --env LABMCP_READ_ONLY=<LABMCP_READ_ONLY> --env LABMCP_LIMITS=<LABMCP_LIMITS> --transport stdio sartorius-balance -- uvx labmcp-sartorius
Open on GitHub

What Sartorius Balance does

The server connects to Sartorius balances (Cubis MSE, Cubis II MCA, Secura, Quintix, Practum, Entris II and older CP/CPA series with --option legacy=true) via RS-232, USB or Ethernet and sends ASCII commands over the SBI protocol. The agent can read current weight, wait for a stable value, zero or tare the balance, record a weight series to track evaporation or moisture uptake, adapt the filter for draughty or vibrating benches, lock the keypad and run internal adjustment with the built-in weight on isoCAL models.

The server uses factory interface settings: 9600 baud, 8 data bits, odd parity, 1 stop bit. The balance must be set to SBI protocol with manual output, no stability check and auto print off. Without Python and the uvx package the server will not start. The --read-only flag allows weighing only and blocks taring, zeroing and adjustment. The max_series_duration_s limit caps logging series length at 600 seconds by default; override it at launch.

What it helps with

  • weigh samples and wait for stable readings
  • tare containers and zero the balance
  • log a series of readings to calculate evaporation or drift rate
  • switch the balance filter to handle draughts or vibration
  • run internal adjustment with the built-in weight

Example prompts for the agent

  • Log the weight every 10 seconds for 5 minutes and calculate the evaporation rate in mg/min
  • Set the balance filter to handle drafts and lock the keypad

How to install Sartorius Balance

Platform CLI

claude mcp add --env LABMCP_ADDRESS=<LABMCP_ADDRESS> --env LABMCP_SIMULATE=<LABMCP_SIMULATE> --env LABMCP_READ_ONLY=<LABMCP_READ_ONLY> --env LABMCP_LIMITS=<LABMCP_LIMITS> --transport stdio sartorius-balance -- uvx labmcp-sartorius

Replace <…> with your own values. uvx runs the command named after the package; if the README names another one, use uvx --from labmcp-sartorius <command>

Step by step, with commands for each platform: How to add an MCP server to Claude Code, Codex, Cursor, VS Code, Gemini CLI and more

Questions about Sartorius Balance

How do I install Sartorius Balance in Claude Code?

Run claude mcp add labmcp-sartorius -- uvx labmcp-sartorius. To connect to real hardware, add the --address flag with the port: /dev/ttyUSB0 on Linux, /dev/tty.usbmodem14201 on macOS, COM4 on Windows or tcp://192.168.1.61:49155 for Ethernet.

What does Sartorius Balance do?

It is an MCP server for controlling Sartorius laboratory balances over the SBI ASCII protocol. The agent can weigh, tare, log measurement series, adjust the filter and run internal calibration.

Which Sartorius balances does this server support?

Cubis MSE, Cubis II MCA, Secura, Quintix, Practum, Entris II. Older CP and CPA models work with --option legacy=true. Other SBI balances are likely compatible.

Similar MCP servers

All MCP servers for Science and research →

From the same set30

The whole set →
SRS Residual Gas Analyzer This MCP server lets an AI agent inspect SRS residual-gas analyzers, read spectra and pressure, screen gas peaks, and run helium leak checks. CX Codex +1 ★ 32repo stars SRS Lock-in Amplifier SRS Lock-in Amplifier lets an agent drive Stanford Research Systems lock-ins: read X/Y/R/θ, set frequency, phase and sensitivity, run frequency sweeps. CX Codex +1 ★ 32repo stars SiLA 2 Bridge SiLA 2 Bridge connects AI agents to laboratory instruments via the SiLA 2 standard over gRPC. Useful for running automated pipetters and plate readers. CX Codex +1 ★ 32repo stars Generic SCPI Instrument Generic SCPI Instrument is an MCP server for Claude Code that connects an AI agent to SCPI equipment over VISA, TCP, or serial links. Read data and send commands from chat. CX Codex +1 ★ 32repo stars Rigol Oscilloscope Controls Rigol oscilloscopes over SCPI via USB or LAN. Allows agents to adjust timebases, capture calibrated waveforms, read voltages and take screenshots. CX Codex +1 ★ 32repo stars Pfeiffer Vacuum Gauge Controller Pfeiffer Vacuum Gauge Controller is a Claude Code MCP server that reads and records pressure from Pfeiffer TPG controllers, identifies connected gauges, and controls ionisation gauges during pump-down checks. CX Codex +1 ★ 32repo stars Opentrons OT-2 / Flex Opentrons OT-2 / Flex is an MCP server for Claude Code that connects Flex and OT-2 robots via HTTP API, uploads protocols, inspects deck layouts, and tracks runs. CX Codex +1 ★ 32repo stars Ocean Insight Spectrometer Connect an Ocean Insight spectrometer to an AI agent to capture spectra and measure absorbance or transmittance. A simulator lets you try the server before connecting hardware. CX Codex +1 ★ 32repo stars

Project sponsors

Companies that keep this analytics open