design-fmea-generator — Claude Code skill: DFMEA and ISO 14971
design-fmea-generator runs a design FMEA for a medical device and keeps it tied to ISO 14971: failure modes, S/O/D ratings, RPN and follow-up actions.
MIT 1 installs ★ 1,931 updated 2026-09-16
npx skills add a5c-ai/babysitter --skill design-fmea-generator -a claude-codeWhat design-fmea-generator does
This skill walks a medical device design through DFMEA: split it into functions, go over the failure modes, then score severity, occurrence and detection on a 1-10 scale. The RPN comes out of those numbers and lands in a worksheet.
Results can be a worksheet, a summary-report or an action-tracker. The config puts the RPN action limit at 100 and treats severity 9 as critical. Entries link back to AIAG templates and the ISO 14971 risk management file; file reads, edits, grep and Bash cover the tooling it uses.
It only makes sense once the design concept is settled, functional requirements are written down, intended use is known and you have failure history for comparable devices. Skip that last part and the occurrence column turns into guesswork.
What it helps with
- break a device design into functions and failure modes
- score severity, occurrence and detection, then compute RPN
- flag rows above the RPN action limit or at critical severity
- tie the worksheet to the ISO 14971 risk file
- track recommended actions through to closure
Example prompts for the agent
- Build a DFMEA for the infusion pump design with S/O/D scores and an RPN action limit of 100.
- Rework the failure modes after the housing material change and update the occurrence ratings.
- Give me a
summary-reportof the current DFMEA plus an action list for the design review.
How to install design-fmea-generator
1Skills CLI (Vercel)
npx skills add a5c-ai/babysitter --skill design-fmea-generator -a claude-code2Manually: put the files in place
~/.claude/skills/design-fmea-generator/SKILL.mdCopy the whole skill folder; for one project use .claude/skills/design-fmea-generator/
1Skills CLI (Vercel)
npx skills add a5c-ai/babysitter --skill design-fmea-generator -a codex2Manually: put the files in place
.agents/skills/design-fmea-generator/SKILL.mdFor all projects use ~/.agents/skills/
1Skills CLI (Vercel)
npx skills add a5c-ai/babysitter --skill design-fmea-generator -a cursor2Manually: put the files in place
.cursor/skills/design-fmea-generator/SKILL.mdCursor also reads .agents/skills/ and .claude/skills/
1GitHub CLI
gh skill install a5c-ai/babysitter library/specializations/domains/science/biomedical-engineering/skills/design-fmea-generator2Manually: put the files in place
.github/skills/design-fmea-generator/SKILL.md1Skills CLI (Vercel)
npx skills add a5c-ai/babysitter --skill design-fmea-generator -a gemini-cli2Platform CLI
gemini skills install https://github.com/a5c-ai/babysitter --path library/specializations/domains/science/biomedical-engineering/skills/design-fmea-generatorManually: put the files in place
.devin/skills/design-fmea-generator/SKILL.mdThe legacy .windsurf/skills/ path still works
Skills CLI (Vercel)
npx skills add a5c-ai/babysitter --skill design-fmea-generator -a opencodeClaude.ai
Zip the folder and upload it in Settings → Capabilities → Skills
Step by step, with commands for each platform: How to install skills in Claude Code: five ways
Questions about design-fmea-generator
How do I install design-fmea-generator in Claude Code?
Run npx skills add a5c-ai/babysitter --skill design-fmea-generator -a claude-code. The skill file lands at ~/.claude/skills/design-fmea-generator/SKILL.md.
What does design-fmea-generator do?
It generates a design FMEA worksheet, suggests failure modes, guides the severity, occurrence and detection ratings, calculates RPN and keeps a recommended-action list linked to ISO 14971.
What do I need before running it?
A defined design concept, documented functional requirements, an established intended use and failure data from similar devices. AIAG templates and an ISO 14971 risk management file are used alongside.
Source text
SKILL.md · MIT
---
name: design-fmea-generator
description: Design Failure Mode and Effects Analysis (DFMEA) skill for systematic design risk identification
allowed-tools:
- Read
- Write
- Glob
- Grep
- Edit
- Bash
metadata:
specialization: biomedical-engineering
domain: science
category: Risk Management
skill-id: BME-SK-007
graph:
domains: [domain:biomedical-engineering]
skillAreas: [skill-area:statistical-analysis, skill-area:data-analysis, skill-area:compliance-automation]
workflows: [workflow:experiment-design, workflow:peer-review-cycle]
roles: [role:biomedical-engineer, role:research-engineer]
---
# Design FMEA Generator Skill
## Purpose
The Design FMEA Generator Skill facilitates systematic identification and evaluation of potential design failure modes for medical devices, supporting ISO 14971 risk management through structured DFMEA methodology.
## Capabilities
- DFMEA worksheet generation
- Failure mode brainstorming support
- Severity, Occurrence, Detection rating guidance
- RPN (Risk Priority Number) calculation
- Recommended action tracking
- Control plan linkage
- Failure mode categorization
- Root cause analysis templates
- Design mitigation recommendations
- DFMEA revision management
- Cross-reference to risk management file
## Usage Guidelines
### When to Use
- Initiating design risk analysis
- Evaluating design alternatives
- Supporting design reviews
- Updating risk assessments for design changes
### Prerequisites
- Design concept defined
- Functional requirements documented
- Intended use established
- Similar device failure data available
### Best Practices
- Conduct DFMEA early in design phase
- Include cross-functional team members
- Link to ISO 14971 risk management file
- Update with design iterations
## Process Integration
This skill integrates with the following processes:
- Medical Device Risk Management (ISO 14971)
- Design Control Process Implementation
- Design for Manufacturing and Assembly (DFMA)
- Verification and Validation Test Planning
## Dependencies
- AIAG FMEA templates
- ISO 14971 risk management framework
- Design documentation
- Historical failure data
- Industry failure mode databases
## Configuration
```yaml
design-fmea-generator:
rating-scales:
severity: 1-10
occurrence: 1-10
detection: 1-10
risk-thresholds:
rpn-action-limit: 100
severity-critical: 9
output-formats:
- worksheet
- summary-report
- action-tracker
```
## Output Artifacts
- DFMEA worksheets
- Failure mode catalogs
- RPN summary reports
- Recommended action lists
- Control plan inputs
- Design review inputs
- Risk management file updates
- Mitigation tracking logs
## Quality Criteria
- All design functions analyzed
- Failure modes comprehensively identified
- Ratings consistently applied
- High RPN items addressed
- Actions tracked to completion
- Linkage to ISO 14971 maintained
© a5c-ai · MIT · a5c-ai/babysitter