What mdr-745-specialist does

The skill walks through device classification under Annex VIII. It checks duration, invasiveness, contact with body systems, energy dependence, and rules 1-22; for software, it uses the MDCG 2019-11 algorithm. Classification still needs confirmation with a Notified Body.

For technical documentation, it lays out the Annex II and III file: device description, labeling and IFU, design and manufacturing information, GSPR matrix, benefit-risk analysis, verification and validation evidence, ISO 14971 risk management, and the clinical evaluation report. Annex XIV guidance covers clinical claims, literature review, equivalence, evidence gaps, and CER preparation.

It also structures PMS under Chapter VII, including complaint handling, vigilance, PSUR timing under Art. 86, PMCF links, trend analysis, EUDAMED, and UDI. A CER requires review by a qualified evaluator with a medical or equivalent healthcare qualification, 4+ years of relevant clinical experience, and clinical evaluation training. Install it when you are working through an MDR dossier; use Notified Body review for the final compliance check.

What it helps with

  • classify a medical device under Annex VIII
  • check an Annex II and III technical file
  • plan clinical evaluation and a CER
  • set the PSUR schedule for a device class
  • connect PMS activities with PMCF, EUDAMED, and UDI

Example prompts for the agent

  • What class is my device under MDR? Show the Annex VIII reasoning.
  • Review my technical file against Annex II and III and flag gaps.
  • Build a PSUR schedule under Art. 86 for a Class IIb device.

How to install mdr-745-specialist

1Plugin marketplace

/plugin marketplace add alirezarezvani/claude-skills
/plugin install ra-qm-skills@claude-code-skills

This installs the whole ra-qm-skills plugin with all its skills

2Skills CLI (Vercel)

npx skills add alirezarezvani/claude-skills --skill mdr-745-specialist -a claude-code

3Manually: put the files in place

~/.claude/skills/mdr-745-specialist/SKILL.md

Copy the whole skill folder; for one project use .claude/skills/mdr-745-specialist/

From the same set349

The whole set →
engineering-skills Alireza Rezvani An engineering skill index for Claude Code that helps you select one specialist SKILL.md for the task at hand. It covers architecture, testing, DevOps, and data work. Claude Code 2,387installs finance-skills Alireza Rezvani Routes ambiguous finance prompts to the right bundled skill: financial-analyst, saas-metrics-coach, or month-end-close. Claude Code 2,312installs marketing-skills Alireza Rezvani A directory and router for marketing skills in Claude Code. It picks the right specialist skill for SEO, content, CRO, channels, and related tasks. Claude Code 2,264installs business-growth-skills Alireza Rezvani Routes growth and revenue prompts to the right specialized skill across customer success, sales engineering, RevOps, and proposals in Claude Code. Claude Code 2,189installs engineering-advanced-skills Alireza Rezvani An index of 37 engineering skills for architecture, automation, reliability, and platform work. Use it when a project needs task-specific engineering workflows. Claude Code 2,019installs product-skills Alireza Rezvani Product work orchestrator for Claude Code. Routes queries across 16 domain lanes and validates discovery trees with deterministic scripts. Claude Code 1,994installs pm-skills Alireza Rezvani Routes project-delivery requests across 8 PM sub-skills for Jira, Confluence, sprints, reporting, and team communication. Useful for controlled delivery work. Claude Code 1,975installs senior-backend Alireza Rezvani Scaffolds backend APIs, detects database bottlenecks, and runs load tests. Useful when designing Express routes, optimizing PostgreSQL, or preparing for production. Claude Code 1,674installs

Similar

Questions about mdr-745-specialist

How do I install mdr-745-specialist in Claude Code?

Run npx skills add alirezarezvani/claude-skills --skill mdr-745-specialist -a claude-code. The skill file is also available at ~/.claude/skills/mdr-745-specialist/SKILL.md.

What does mdr-745-specialist do?

It supports EU MDR 2017/745 work across device classification, technical documentation, clinical evidence, PMS, PSUR planning, EUDAMED, and UDI.

What does it require for a clinical evaluation report?

The workflow covers claims and endpoints, literature searching, data appraisal, equivalence, evidence gaps, and CER preparation under Annex XIV. The CER should be reviewed by a qualified evaluator.

Source text

SKILL.md · MIT
---
name: "mdr-745-specialist"
description: EU MDR 2017/745 compliance specialist for medical device classification, technical documentation, clinical evidence, and post-market surveillance. Covers Annex VIII classification rules, Annex II/III technical files, Annex XIV clinical evaluation, Art. 86 PSUR schedules, and EUDAMED integration. Use when classifying a medical device under MDR, building or gap-checking a technical file, planning clinical evaluation or PMS/PSUR cadence, or preparing for notified body review (e.g., 'what class is my device under MDR', 'review my PSUR schedule').
metadata:
  triggers:
    - MDR compliance
    - EU MDR
    - medical device classification
    - Annex VIII
    - technical documentation
    - clinical evaluation
    - PMCF
    - EUDAMED
    - UDI
    - notified body
---

# MDR 2017/745 Specialist

EU MDR compliance patterns for medical device classification, technical documentation, and clinical evidence.

---

## Table of Contents

- [Device Classification Workflow](#device-classification-workflow)
- [Technical Documentation](#technical-documentation)
- [Clinical Evidence](#clinical-evidence)
- [Post-Market Surveillance](#post-market-surveillance)
- [EUDAMED and UDI](#eudamed-and-udi)
- [Reference Documentation](#reference-documentation)
- [Tools](#tools)

---

## Device Classification Workflow

Classify device under MDR Annex VIII:

1. Identify device duration (transient, short-term, long-term)
2. Determine invasiveness level (non-invasive, body orifice, surgical)
3. Assess body system contact (CNS, cardiac, other)
4. Check if active device (energy dependent)
5. Apply classification rules 1-22
6. For software, apply MDCG 2019-11 algorithm
7. Document classification rationale
8. **Validation:** Classification confirmed with Notified Body

### Classification Matrix

| Factor | Class I | Class IIa | Class IIb | Class III |
|--------|---------|-----------|-----------|-----------|
| Duration | Any | Short-term | Long-term | Long-term |
| Invasiveness | Non-invasive | Body orifice | Surgical | Implantable |
| System | Any | Non-critical | Critical organs | CNS/cardiac |
| Risk | Lowest | Low-medium | Medium-high | Highest |

### Software Classification (MDCG 2019-11)

| Information Use | Condition Severity | Class |
|-----------------|-------------------|-------|
| Informs decision | Non-serious | IIa |
| Informs decision | Serious | IIb |
| Drives/treats | Critical | III |

### Classification Examples

**Example 1: Absorbable Surgical Suture**
- Rule 8 (implantable, long-term)
- Duration: > 30 days (absorbed)
- Contact: General tissue
- Classification: **Class IIb**

**Example 2: AI Diagnostic Software**
- Rule 11 + MDCG 2019-11
- Function: Diagnoses serious condition
- Classification: **Class IIb**

**Example 3: Cardiac Pacemaker**
- Rule 8 (implantable)
- Contact: Central circulatory system
- Classification: **Class III**

---

## Technical Documentation

Prepare technical file per Annex II and III:

1. Create device description (variants, accessories, intended purpose)
2. Develop labeling (Article 13 requirements, IFU)
3. Document design and manufacturing process
4. Complete GSPR compliance matrix
5. Prepare benefit-risk analysis
6. Compile verification and validation evidence
7. Integrate risk management file (ISO 14971)
8. **Validation:** Technical file reviewed for completeness

### Technical File Structure

```
ANNEX II TECHNICAL DOCUMENTATION
├── Device description and UDI-DI
├── Label and instructions for use
├── Design and manufacturing info
├── GSPR compliance matrix
├── Benefit-risk analysis
├── Verification and validation
└── Clinical evaluation report
```

### GSPR Compliance Checklist

| Requirement | Evidence | Status |
|-------------|----------|--------|
| Safe design (GSPR 1-3) | Risk management file | ☐ |
| Chemical properties (GSPR 10.1) | Biocompatibility report | ☐ |
| Infection risk (GSPR 10.2) | Sterilization validation | ☐ |
| Software requirements (GSPR 17) | IEC 62304 documentation | ☐ |
| Labeling (GSPR 23) | Label artwork, IFU | ☐ |

### Conformity Assessment Routes

| Class | Route | NB Involvement |
|-------|-------|----------------|
| I | Annex II self-declaration | None |
| Is/Im | Annex II + IX/XI | Sterile/measuring aspects |
| IIa | Annex II + IX or XI | Product or QMS |
| IIb | Annex IX, or Annex X + XI | QMS + tech doc assessment, or type exam + production |
| III | Annex IX, or Annex X + XI | Full QMS + product dossier, or type exam + production |

---

## Clinical Evidence

Develop clinical evidence strategy per Annex XIV:

1. Define clinical claims and endpoints
2. Conduct systematic literature search
3. Appraise clinical data quality
4. Assess equivalence (technical, biological, clinical)
5. Identify evidence gaps
6. Determine if clinical investigation required
7. Prepare Clinical Evaluation Report (CER)
8. **Validation:** CER reviewed by qualified evaluator

### Evidence Requirements by Class

| Class | Minimum Evidence | Investigation |
|-------|------------------|---------------|
| I | Risk-benefit analysis | Not typically required |
| IIa | Literature + post-market | May be required |
| IIb | Systematic literature review | Often required |
| III | Comprehensive clinical data | Required (Article 61) |

### Clinical Evaluation Report Structure

```
CER CONTENTS
├── Executive summary
├── Device scope and intended purpose
├── Clinical background (state of the art)
├── Literature search methodology
├── Data appraisal and analysis
├── Safety and performance conclusions
├── Benefit-risk determination
└── PMCF plan summary
```

### Qualified Evaluator Requirements

- Medical degree or equivalent healthcare qualification
- 4+ years clinical experience in relevant field
- Training in clinical evaluation methodology
- Understanding of MDR requirements

---

## Post-Market Surveillance

Establish PMS system per Chapter VII:

1. Develop PMS plan (Article 84)
2. Define data collection methods
3. Establish complaint handling procedures
4. Create vigilance reporting process
5. Plan Periodic Safety Update Reports (PSUR)
6. Integrate with PMCF activities
7. Define trend analysis and signal detection
8. **Validation:** PMS system audited annually

### PMS System Components

| Component | Requirement | Frequency |
|-----------|-------------|-----------|
| PMS Plan | Article 84 | Maintain current |
| PSUR | Article 86 — Class IIa and higher | Per Art. 86(1) schedule below |
| PMCF Plan | Annex XIV Part B | Update with CER |
| PMCF Report | Annex XIV Part B | Annual (Class III) |
| Vigilance | Articles 87-92 | As events occur |

### PSUR Schedule

| Class | Frequency (MDR Art. 86(1)) |
|-------|-----------------------------|
| Class III | Updated at least annually |
| Class IIb (all, incl. implantable) | Updated at least annually |
| Class IIa | When necessary, at least every 2 years |
| Class I | No PSUR — PMS report instead (Art. 85) |

### Serious Incident Reporting

| Timeline | Requirement |
|----------|-------------|
| 2 days | Serious public health threat |
| 10 days | Death or serious deterioration |
| 15 days | Other serious incidents |

---

## EUDAMED and UDI

Implement UDI system per Article 27:

1. Obtain issuing entity code (GS1, HIBCC, ICCBBA)
2. Assign UDI-DI to each device variant
3. Assign UDI-PI (production identifier)
4. Apply UDI carrier to labels (AIDC + HRI)
5. Register actor in EUDAMED
6. Register devices in EUDAMED
7. Upload certificates when available
8. **Validation:** UDI verified on sample labels

### EUDAMED Modules

| Module | Content | Actor |
|--------|---------|-------|
| Actor | Company registration | Manufacturer, AR |
| UDI/Device | Device and variant data | Manufacturer |
| Certificates | NB certificates | Notified Body |
| Clinical Investigation | Study registration | Sponsor |
| Vigilance | Incident reports | Manufacturer |
| Market Surveillance | Authority actions | Competent Authority |

### UDI Label Requirements

Required elements per Article 13:

- [ ] UDI-DI (device identifier)
- [ ] UDI-PI (production identifier) for Class II+
- [ ] AIDC format (barcode/RFID)
- [ ] HRI format (human-readable)
- [ ] Manufacturer name and address
- [ ] Lot/serial number
- [ ] Expiration date (if applicable)

---

## Reference Documentation

### MDR Classification Guide

`references/mdr-classification-guide.md` contains:

- Complete Annex VIII classification rules (Rules 1-22)
- Software classification per MDCG 2019-11
- Worked classification examples
- Conformity assessment route selection

### Clinical Evidence Requirements

`references/clinical-evidence-requirements.md` contains:

- Clinical evidence framework and hierarchy
- Literature search methodology
- Clinical Evaluation Report structure
- PMCF plan and evaluation report guidance

### Technical Documentation Templates

`references/technical-documentation-templates.md` contains:

- Annex II and III content requirements
- Design History File structure
- GSPR compliance matrix template
- Declaration of Conformity template
- Notified Body submission checklist

---

## Tools

### MDR Gap Analyzer

```bash
# Quick gap analysis
python scripts/mdr_gap_analyzer.py --device "Device Name" --class IIa

# JSON output for integration
python scripts/mdr_gap_analyzer.py --device "Device Name" --class III --output json

# Interactive assessment
python scripts/mdr_gap_analyzer.py --interactive
```

Analyzes device against MDR requirements, identifies compliance gaps, generates prioritized recommendations.

**Output includes:**
- Requirements checklist by category
- Gap identification with priorities
- Critical gap highlighting
- Compliance roadmap recommendations

---

## Notified Body Interface

### Selection Criteria

| Factor | Considerations |
|--------|----------------|
| Designation scope | Covers your device type |
| Capacity | Timeline for initial audit |
| Geographic reach | Markets you need to access |
| Technical expertise | Experience with your technology |
| Fee structure | Transparency, predictability |

### Pre-Submission Checklist

- [ ] Technical documentation complete
- [ ] GSPR matrix fully addressed
- [ ] Risk management file current
- [ ] Clinical evaluation report complete
- [ ] QMS (ISO 13485) certified
- [ ] Labeling and IFU finalized
- [ ] **Validation:** Internal gap assessment complete

© Alireza Rezvani · MIT · alirezarezvani/claude-skills

See also

Project sponsors

Companies that keep this analytics open
Gold sponsor

Impressions, clicks and code copies — open statistics. We keep the numbers public for the same reason NeBlask itself is public. Become a sponsor