asd-ste100 · surendranb — Claude Code skill: what it does, how to install
Enforces ASD-STE100 Simplified Technical English rules for procedures and manuals so readers grasp the exact intended meaning without confusion.
npx skills add surendranb/writing-skills --skill asd-ste100 -a claude-codeWhat asd-ste100 does
This skill directs the agent to generate technical procedures, warning blocks, and maintenance guides following the ASD-STE100 specification. The foundation rests on a single principle: one word holds only one meaning. All instructional steps begin with an active imperative verb rather than passive phrasing or polite suggestions.
The workflow enforces strict structural ceilings. Procedural sentences cannot exceed 20 words, while descriptive statements stop at 25 words. Chains of stacked nouns are capped at three items. The skill also requires putting conditional clauses at the start of a sentence and replacing ambiguous pronouns with clear technical terms. Detailed formatting for safety alerts (WARNING, CAUTION, NOTE) resides in references/REFERENCE.md, which the agent reads on demand.
Operating this skill requires only standard Markdown support within the agent environment, with no external toolchains needed.
What it helps with
- convert technical procedures into Simplified Technical English
- enforce a 20-word limit on instructional sentences
- eliminate noun clusters and ambiguous pronouns in manuals
- rewrite passive instructions into active imperative voice
Example prompts for the agent
- Rewrite this maintenance manual using ASD-STE100 rules
- Check this procedure for noun clusters and sentence length violations
- Convert this draft into imperative instructions under 20 words per step
How to install asd-ste100
1Skills CLI (Vercel)
npx skills add surendranb/writing-skills --skill asd-ste100 -a claude-code2Manually: put the files in place
~/.claude/skills/asd-ste100/SKILL.mdCopy the whole skill folder; for one project use .claude/skills/asd-ste100/
1Skills CLI (Vercel)
npx skills add surendranb/writing-skills --skill asd-ste100 -a codex2Manually: put the files in place
.agents/skills/asd-ste100/SKILL.mdFor all projects use ~/.agents/skills/
1Skills CLI (Vercel)
npx skills add surendranb/writing-skills --skill asd-ste100 -a cursor2Manually: put the files in place
.cursor/skills/asd-ste100/SKILL.mdCursor also reads .agents/skills/ and .claude/skills/
1GitHub CLI
gh skill install surendranb/writing-skills asd-ste1002Manually: put the files in place
.github/skills/asd-ste100/SKILL.md1Skills CLI (Vercel)
npx skills add surendranb/writing-skills --skill asd-ste100 -a gemini-cli2Platform CLI
gemini skills install https://github.com/surendranb/writing-skills --path skills/asd-ste100Manually: put the files in place
.devin/skills/asd-ste100/SKILL.mdThe legacy .windsurf/skills/ path still works
Skills CLI (Vercel)
npx skills add surendranb/writing-skills --skill asd-ste100 -a opencodeClaude.ai
Zip the folder and upload it in Settings → Capabilities → Skills
Step by step, with commands for each platform: How to install skills in Claude Code: five ways
Questions about asd-ste100
How do I install asd-ste100 in Claude Code?
Run npx skills add surendranb/writing-skills --skill asd-ste100 -a claude-code in your terminal.
What does the asd-ste100 skill do?
It enforces Simplified Technical English rules, restricting vocabulary, banning passive voice in steps, and capping sentence lengths to remove ambiguity.
What are the sentence length limits under asd-ste100?
Procedural sentences have a limit of 20 words, while descriptive sentences can contain up to 25 words.
Source text
SKILL.md · MIT
---
name: asd-ste100
description: Use when writing technical procedures, instructions, warnings, maintenance manuals, or any text where every reader including non-native English speakers must understand exactly one meaning.
compatibility: Requires standard Markdown parser and agent context
---
# ASD-STE100 Simplified Technical English
Control vocabulary and syntax to eliminate ambiguity in technical documentation.
## The core rule
**One word, one meaning. Imperative voice for instructions. Maximum 20 words per sentence.**
Workflow: `choose approved STE vocabulary` → `write imperative command` → `restrict sentence length to 20 words max` → `verify zero ambiguity`.
## Mechanics
1. **Approved vocabulary.** Use only words from the ASD-STE100 dictionary or approved technical nouns.
2. **Imperative commands.** Start steps with an action verb ("Remove the bolt", not "You should remove the bolt").
3. **Word count limits.** Maximum 20 words for procedural sentences; maximum 25 words for descriptive sentences.
4. **No noun clusters.** Maximum of 3 nouns in a sequence (e.g. use "valve control switch" instead of "engine fuel system valve control switch").
5. **Present tense.** Describe current states in present tense; avoid future tense ("The light is on" not "The light will turn on").
6. **No gerunds in titles.** Use simple nouns or infinitives for headings.
7. **Explicit conditions.** Place conditional clauses at the beginning of the sentence ("If the pressure is low, replace the filter").
8. **Approved modifiers.** Avoid vague adjectives like "extreme", "rapid", or "normal" unless quantified.
## Verify
- Sentences do not exceed 20 words for procedures
- Every instruction starts with an active imperative verb
- No noun clusters exceeding 3 words
- All technical terms conform to standard dictionary definitions
- Zero ambiguous pronouns (replace "it" or "they" with specific nouns)
## Do not
- Use words with multiple meanings (e.g., use "fast" or "secure", avoid "fixed")
- Write conditional clauses after the main action
- Use contractions or colloquialisms
- Use passive voice in maintenance steps
## References
For the enforceable limits (sentence/paragraph/noun-cluster caps), safety-text structure (WARNING/CAUTION/NOTE), and punctuation rules, read `references/REFERENCE.md` when a draft is borderline or needs verification — load on demand, not upfront.
## Example transformations
**Before:** "It is recommended that technicians should carefully inspect the aforementioned component assembly for any potential signs of wear prior to system operation."
**After:** "Inspect the component assembly for wear before you operate the system."
**Before:** "When the pressure drops too low, you might want to consider resetting the main system valve."
**After:** "If the pressure is low, reset the main valve."
© surendranb · MIT · surendranb/writing-skills
Similar skills
All skills for Writing and docs →asd-ste100 by other authors comes first.