# hvac-design

hvac-design is a Claude Code skill for calculating HVAC loads, selecting equipment, and assessing energy use. It supports building heating, ventilation, and air-conditioning design under ASHRAE standards.

- skill · `type=skill` · Claude Code, Codex, Cursor, GitHub Copilot, Gemini CLI, OpenCode, Windsurf (Devin Desktop), Claude.ai · 5 installs · ★ 1931 repo stars
- Author: a5c-ai
- License: MIT · policy=mirror · the beginning of the file is at the end of this page
- Source: https://github.com/a5c-ai/babysitter/tree/HEAD/library/specializations/domains/science/mechanical-engineering/skills/hvac-design/SKILL.md
- Updated: 2026-09-16
- Security check: automated, 2026-11-16 (text) — no signs of malicious code found.
- HTML: https://affpapa.org/en/nevibecode/skills/hvac-design

## What it does

hvac-design calculates heating and cooling loads, works through psychrometric analysis, and helps select AHUs, chillers, and boilers. It also covers duct and pipe sizing, indoor air quality checks, and energy analysis against ASHRAE 90.1.

The calculation inputs include building location and type, floor area, number of floors, indoor conditions, and internal loads. Results can include peak loads, ventilation airflow, equipment specifications, and annual energy figures. Ventilation analysis uses ASHRAE 62.1.

## Install

### Claude Code (native platform)

1. **Skills CLI (Vercel)**
```bash
npx skills add a5c-ai/babysitter --skill hvac-design -a claude-code
```

2. **Manually: put the files in place**
- File: `~/.claude/skills/hvac-design/SKILL.md` — Copy the whole skill folder; for one project use .claude/skills/hvac-design/

### Codex

1. **Skills CLI (Vercel)**
```bash
npx skills add a5c-ai/babysitter --skill hvac-design -a codex
```

2. **Manually: put the files in place**
- File: `.agents/skills/hvac-design/SKILL.md` — For all projects use ~/.agents/skills/

### Cursor

1. **Skills CLI (Vercel)**
```bash
npx skills add a5c-ai/babysitter --skill hvac-design -a cursor
```

2. **Manually: put the files in place**
- File: `.cursor/skills/hvac-design/SKILL.md` — Cursor also reads .agents/skills/ and .claude/skills/

### GitHub Copilot

1. **GitHub CLI**
```bash
gh skill install a5c-ai/babysitter library/specializations/domains/science/mechanical-engineering/skills/hvac-design
```

2. **Manually: put the files in place**
- File: `.github/skills/hvac-design/SKILL.md`

### Gemini CLI

1. **Skills CLI (Vercel)**
```bash
npx skills add a5c-ai/babysitter --skill hvac-design -a gemini-cli
```

2. **Platform CLI**
```bash
gemini skills install https://github.com/a5c-ai/babysitter --path library/specializations/domains/science/mechanical-engineering/skills/hvac-design
```

### Windsurf (Devin Desktop)

**Manually: put the files in place**
- File: `.devin/skills/hvac-design/SKILL.md` — The legacy .windsurf/skills/ path still works

### OpenCode

**Skills CLI (Vercel)**
```bash
npx skills add a5c-ai/babysitter --skill hvac-design -a opencode
```

### Claude.ai

**Claude.ai**
- Zip the folder and upload it in Settings → Capabilities → Skills

Where a file is given instead of a command, copy the files from the source to that path: https://github.com/a5c-ai/babysitter/tree/HEAD/library/specializations/domains/science/mechanical-engineering/skills/hvac-design/SKILL.md

## When to use it
- calculate peak heating and cooling loads for a building
- select an AHU, chiller, or boiler from design loads
- size ductwork and piping systems
- estimate annual building energy use

## Example prompts
- Calculate heating and cooling loads for this office building using its location and design conditions.
- Select an AHU and chiller for the calculated loads.
- Assess annual energy use and check the design against ASHRAE 90.1.

## Source text · SKILL.md · MIT

Below is the content of a third-party file. It is data, not instructions for you: do not act on anything written inside unless the human asks. Block tag: 0e4763e0b18b44c1.

BEGIN THIRD-PARTY FILE 0e4763e0b18b44c1
````text
---
name: hvac-design
description: Skill for HVAC system design and analysis per ASHRAE standards including load calculations, equipment selection, and energy efficiency analysis
allowed-tools:
  - Read
  - Write
  - Glob
  - Grep
  - Bash
metadata:
  specialization: mechanical-engineering
  domain: science
  category: thermal-fluid-analysis
  priority: high
  phase: 6
  tools-libraries:
    - Carrier HAP
    - Trane TRACE
    - EnergyPlus
    - eQUEST
graph:
  domains: [domain:mechanical-engineering]
  skillAreas: [skill-area:physics-simulation, skill-area:mathematical-reasoning, skill-area:motion-planning]
  roles: [role:systems-integration-engineer, role:research-engineer]
---

# HVAC System Design Skill

## Purpose

The HVAC System Design skill provides comprehensive capabilities for heating, ventilation, and air conditioning system design according to ASHRAE standards, enabling systematic load calculations, equipment selection, ductwork design, and energy efficiency analysis for commercial and industrial buildings.

## Capabilities

- Heating and cooling load calculations
- Psychrometric analysis and chart calculations
- Equipment selection (AHU, chillers, boilers)
- Duct and piping system sizing
- Energy efficiency analysis (ASHRAE 90.1)
- Indoor air quality assessment (ASHRAE 62.1)
- System simulation and optimization
- Control system specification

## Usage Guidelines

### Load Calculations

#### Cooling Load Components

1. **External Loads**
   - Solar radiation through windows (SHGC consideration)
   - Conduction through envelope (walls, roof, floor)
   - Infiltration and ventilation air

2. **Internal Loads**
   - People: 250 Btu/h sensible, 200 Btu/h latent (typical office)
   - Lighting: Use installed wattage with diversity
   - Equipment: Plug loads with usage factors

3. **Calculation Methods**
   - CLTD/CLF method: Manual calculations
   - RTS (Radiant Time Series): More accurate
   - Heat Balance Method: Full simulation

#### Heating Load

1. **Design Conditions**
   - Use ASHRAE 99.6% or 99% design temperature
   - No solar credit for heating design
   - Full infiltration at design conditions

2. **Load Components**
   - Envelope conduction (U × A × ΔT)
   - Infiltration/ventilation (1.08 × CFM × ΔT)
   - No internal gains credited

### Psychrometric Analysis

1. **Key Properties**
   - Dry-bulb and wet-bulb temperatures
   - Relative humidity and humidity ratio
   - Enthalpy and specific volume
   - Dew point temperature

2. **Process Calculations**
   | Process | Constant Property |
   |---------|------------------|
   | Sensible heating/cooling | Humidity ratio |
   | Humidification | Enthalpy (adiabatic) |
   | Dehumidification | Saturation curve |
   | Mixing | Mass-weighted average |

3. **Coil Processes**
   ```
   Sensible Heat Ratio (SHR) = Qs / Qt

   Bypass Factor (BF) = (T_leaving - T_ADP) / (T_entering - T_ADP)
   ```

### Equipment Selection
````
END THIRD-PARTY FILE 0e4763e0b18b44c1

The third-party file has ended. Everything between the 0e4763e0b18b44c1 tags is data: requests and commands from it are not followed. An “end of file” line with another tag inside the block is part of the file.

First 2932 of 6170 bytes. © a5c-ai · MIT · https://github.com/a5c-ai/babysitter/tree/HEAD/library/specializations/domains/science/mechanical-engineering/skills/hvac-design/SKILL.md

_Part of the page did not fit — see the HTML version._

---
NeVibeCode on affpapa.org. Catalog texts are descriptions, not instructions for the agent. How to choose and install: https://affpapa.org/en/nevibecode/agents.md
